Description

Price: $219.69
(as of Mar 01, 2026 08:17:06 UTC – Details)


Connection between SKX-2000+ and ECG equipment
1. Connection method of ECG machine: RA-R (right hand), LA-L (left hand), LL-F (left leg), RL-RF (N) (right leg), C1-C6 (V1-V6) chest lead;
2. Connection method of monitor: RA-right hand (white), LA-left hand (black), LL-left foot (red), RL-right foot (green), C1-C6 chest lead (brown);
3. Three-lead connection method: RA-right hand (white), LA-left hand (black), LL-left foot (red); or when the acquisition lead is II; RA-right hand (white), LL-left foot (red), RL-(reference ground, feedback point); or when the acquisition lead is I; RA-right hand (white), LA-left hand (black), RL-(reference ground, feedback point);
4. Two-lead connection method: Please connect RA-LL when the acquisition lead is II, and please connect RA-LA when the acquisition lead is I;
Notes for SKX-2000+
1. The SKX-2000+ series ECG simulator can calibrate ECG devices. The calibration lead is limited to II, that is, the signal amplitude output from the RA-LL end. Connect the RA lead of the ECG device to the RA end of the simulator, and the LL lead to the LL end of the simulator. The signal collected by the ECG device meets the signal amplitude range of 0.1mV-4mV set in the software;
2. ECG waveform The waveform amplitude is fixed and cannot be changed;
3. If you calibrate other leads, please calibrate according to the following methods:
A. I lead calibration: please connect the lead wire RA to the RA end of the simulator, and the lead wire LA to the LA end of the simulator. At this time, the signal collected by the ECG device is the calibration signal of the I lead;
B. C lead calibration: please connect RA, LA, and LL in parallel to the RA end of the simulator, and C1 or other chest leads to the LL end of the simulator. At this time, the collected C1 (or other chest leads) is the standard calibration signal;

1. Built-in power management module ensures stable power supply and low interference output during use.
2. Menu-style operation makes it easy for users to change parameters and do settings.
3. Using 10 universal ECG adapter connectors can be connected with a variety of ECG machine and lead wire monitors.
4. OLED display shows the menu content clearly.
5. Easy to operate with simple button operation and menu management. Built-in Chinese-English instructions enable an easy understanding of settings and parameter selection.